Summary

Prior studies have shown that left ventricular assist device (LVAD) implantation commonly results in right ventricular failure (RVF). Right ventricular dysfunction and failure after LVAD implantation is known to increase morbidity and mortality and contribute to longer post-implant hospital length of stay. Since RVF is difficult to predict and can have harmful effects such as increased ICU stay, adverse outcomes, and mortality, it could be beneficial to preemptively treat patients through preoperative percutaneous right ventricular assist device (RVAD) placement to prevent RVF.

This trial will include both a prospective interventional cohort and a retrospective control cohort. The prospective interventional cohort will consist of patients undergoing LVAD implantation at Massachusetts General Hospital. These patients will receive an RVAD (either the ProtekDuo or Impella RP) prior to LVAD implantation. The historical control cohort will consist of retrospective data collection on patients who have undergone LVAD implantation in the past. This group will be matched with the enrolled prospective interventional patients. The purpose of this study is to compare clinical outcomes of standard of care treatment versus percutaneous RVAD placement preoperatively to LVAD implantation. The investigators hypothesize that the use of the RVAD will mitigate need for inotropic support, reducing the vasoactive-inotrope score (VIS) by 50%, and will improve end organ function in patients compared to standard of care.

Subjects who consent to the study will undergo pre-operative placement of an RVAD, which will be left in up to 72 hours postoperatively. The type of RVAD (Impella RP or ProtekDuo) inserted will be determined by patient needs and venous access and will be up to the discretion of the treating physician. 25 subjects will be enrolled in the prospective interventional cohort and compared to 25 subjects in the matched retrospective control cohort.

Description

Prior studies have shown that left ventricular assist device (LVAD) implantation commonly results in right ventricular failure (RVF). Right ventricular dysfunction and failure after LVAD implantation is known to increase morbidity and mortality and contribute to longer post-implant hospital length of stay. More severe right ventricular failure is highly correlated with poor prognosis and death post-LVAD implantation. In current practice, patients who receive LVADs require right heart support, provided in the form of inotropes. Vasoactive inotrope score (VIS) is a measure that quantifies the amount of right heart support required post-operatively, including dopamine, dobutamine, milrinone, epinephrine, norepinephrine, and vasopressin. It has been used in other studies as a surrogate marker for hemodynamic cardiovascular derangement.

In some cases, right ventricular failure post-LVAD also requires mechanical circulatory support during the perioperative period. Since RVF is difficult to predict and can have harmful effects such as increased ICU stay, adverse outcomes, and mortality, it could be beneficial to preemptively treat patients through preoperative percutaneous right ventricular assist device (RVAD) placement to prevent RVF. The purpose of this study is to test the hypothesis that preemptive use of percutaneous RVADs will mitigate the need for inotropic support in LVAD patients, reducing associated adverse outcomes.

This trial will include both a prospective interventional cohort and a retrospective control cohort. The prospective interventional cohort will consist of patients undergoing LVAD implantation at Massachusetts General Hospital. These patients will receive an RVAD (either the ProtekDuo or Impella RP) prior to LVAD implantation. The historical control cohort will consist of retrospective data collection on patients who have undergone LVAD implantation in the past. This group will be matched with the enrolled prospective interventional patients. The purpose of this study is to compare clinical outcomes of standard of care treatment versus percutaneous RVAD placement preoperatively to LVAD implantation. The investigators hypothesize that the use of the RVAD will mitigate need for inotropic support, reducing the vasoactive-inotrope score (VIS) by 50%, and will improve end organ function in patients compared to standard of care.

There are two types of percutaneous RVADs that will be used in the study: the Impella RP and the ProtekDuo. These devices allow for early intervention in RVF without the need for invasive surgical procedures requiring placement of durable RVADs via thoracotomy or sternotomy. The Impella RP, manufactured by Abiomed, is a heart pump that delivers blood from the inferior vena cava (IVC) to the pulmonary artery (PA). Its insertion is done percutaneously via catheterization through the femoral vein. ProtekDuo, manufactured by TandemLife, is another device placed percutaneously for right heart support via the right internal jugular (RIJ) vein.

Subjects who consent to the study will undergo pre-operative placement of an RVAD, which will be left in up to 72 hours postoperatively. The type of RVAD (Impella RP or ProtekDuo) inserted will be determined by patient needs and venous access and will be up to the discretion of the treating physician. 25 subjects will be enrolled in the prospective interventional cohort and compared to 25 subjects in the matched retrospective control cohort.

Details
Condition Heart failure, Heart failure, Heart disease, Heart disease
Age 18years - 75years
Treatment Percutaneous RVAD
Clinical Study IdentifierNCT04458103
SponsorMassachusetts General Hospital
Last Modified on19 February 2024

Eligibility

Yes No Not Sure

Inclusion Criteria

Ages 18-75
Accepted for LVAD implantation by MGH multidisciplinary team

Exclusion Criteria

Severe tricuspid valve regurgitation in a patient where a valve intervention is expected
Disorders of the pulmonary artery wall that would preclude placement or correct positioning of RVAD
Presence of mechanical valves
Mural thrombosis of the right atrium or vena cava
Anatomic conditions precluding insertion of the RVAD
Known or expected PFO closure
Complicated venous access precluding or complicating device placement (i.e. femoral and jugular thrombosis)
No evidence of right ventricular dysfunction by echocardiogram
Clear my responses

How to participate?

Step 1 Connect with a study center
What happens next?
  • You can expect the study team to contact you via email or phone in the next few days.
  • Sign up as volunteer  to help accelerate the development of new treatments and to get notified about similar trials.

You are contacting

Investigator Avatar

Primary Contact

site

Additional screening procedures may be conducted by the study team before you can be confirmed eligible to participate.

Learn more

If you are confirmed eligible after full screening, you will be required to understand and sign the informed consent if you decide to enroll in the study. Once enrolled you may be asked to make scheduled visits over a period of time.

Learn more

Complete your scheduled study participation activities and then you are done. You may receive summary of study results if provided by the sponsor.

Learn more

Similar trials to consider

Loading...

Browse trials for

Not finding what you're looking for?

Every year hundreds of thousands of volunteers step forward to participate in research. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.

Sign up as volunteer

Study AnnotationsStudy Notes

Notes added here are public and can be viewed by anyone. Notes added here are only available to you and those who you share with.

user name

Added by • 

 • 

Private

Reply by • Private
Loading...

Lorem ipsum dolor sit amet consectetur, adipisicing elit. Ipsa vel nobis alias. Quae eveniet velit voluptate quo doloribus maxime et dicta in sequi, corporis quod. Ea, dolor eius? Dolore, vel!

  The passcode will expire in None.
Loading...

No annotations made yet

Add a private note
  • abc Select a piece of text from the left.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.