Detection of Heart Conditions With Single Lead ECG Using Artificial Intelligence

  • STATUS
    Recruiting
  • participants needed
    600
  • sponsor
    Eko Devices, Inc.
Updated on 19 February 2024

Summary

The purpose of this research is to prospectively test and validate the single-lead Low EF algorithm in outpatients in order to test the performance of a single-lead ECG based algorithm to identify people with decreased left ventricular EF.

Description

Heart failure with reduced left ventricular ejection fraction (EF) is a relatively common cardiac pathology with major clinical implications. People with reduced left ventricular EF are at increased risk for sudden death, ventricular and atrial arrhythmias, and acute hemodynamic decompensation due to heart failure. There are proven medical interventions that prevent sudden cardiac death and complications in people with decreased left ventricular EF. Unfortunately, some people with decreased left ventricular EF are asymptomatic, or have non-specific symptoms like dyspnea, and would not receive those interventions in a timely manner. Currently, there are no effective ways to screen for asymptomatic decreased left ventricular EF in the population, because detection of low EF requires the use of echocardiography. There is a significant need to identify novel technologies that can help to detect people with decreased left ventricular EF in a simple, effective, and reliable manner.

Eko Devices features a cloud-based platform of point-of-care cardiac screening devices and machine learning algorithms that enables more effective detection and management of cardiovascular disease. In this study, we will use the Eko DUO device to collect single-lead ECG data.

The Eko DUO is an FDA-cleared and CE-marked electronic stethoscope that allows audio recording of heart sound to produce a phonocardiogram (PCG) as well as recording a single-lead electrocardiogram (ECG). The DUO features 60x audio amplification, ambient noise reduction, a 4000Hz sample rate, and 4 audio filters. The ECG component is made up of 2 stainless steel electrodes, 0.01Hz high-pass filter, selectable 50/60Hz mains filter, and a 500Hz sample rate. The de-identified auscultatory DUO recordings transmit wirelessly via Bluetooth to the secure, HIPAA-compliant Eko application on a smartphone or tablet, which allows the user to playback heart sound recordings, annotate notes on recorded audio, and save recordings. This data is synced in real-time to a secure, HIPAA-compliant, cloud-based Amazon Web Services (AWS) database server managed by Eko Devices.

It has been previously demonstrated that artificial intelligence processing information from a 12-lead ECG can help to identify people with decreased left ventricular EF1. Using paired 12-lead ECG and echocardiogram data, including the left ventricular ejection fraction, from 44,959 patients at the Mayo Clinic, a convolutional neural was trained to identify patients with low ejection fraction. When tested on an independent set of 52,870 patients, the model showed an Area Under the Curve ("AUC") of 0.93 and an accuracy of 86%. We have also developed a single-lead version of the same algorithm, which will be more easily accessible in a clinical setting since it can be used with a single-lead ECG device like the Eko DUO device. We propose to validate performance of this new model using the current study.

Details
Condition LEFT VENTRICULAR DYSFUNCTION
Age 18-100 years
Treatment Use of Eko DUO electronic stethoscope
Clinical Study IdentifierNCT04400435
SponsorEko Devices, Inc.
Last Modified on19 February 2024

Eligibility

Yes No Not Sure

Inclusion Criteria

English-speaking adults who are 18 years and older
Able and willing to provide informed consent
Complete a clinical echocardiogram within 7 days before or after study procedures

Exclusion Criteria

Unwilling or unable to provide informed consent
Patients who are hospitalized
Clear my responses

How to participate?

Step 1 Connect with a study center
What happens next?
  • You can expect the study team to contact you via email or phone in the next few days.
  • Sign up as volunteer  to help accelerate the development of new treatments and to get notified about similar trials.

You are contacting

Investigator Avatar

Primary Contact

site

Additional screening procedures may be conducted by the study team before you can be confirmed eligible to participate.

Learn more

If you are confirmed eligible after full screening, you will be required to understand and sign the informed consent if you decide to enroll in the study. Once enrolled you may be asked to make scheduled visits over a period of time.

Learn more

Complete your scheduled study participation activities and then you are done. You may receive summary of study results if provided by the sponsor.

Learn more

Similar trials to consider

Loading...

Not finding what you're looking for?

Every year hundreds of thousands of volunteers step forward to participate in research. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.

Sign up as volunteer

user name

Added by • 

 • 

Private

Reply by • Private
Loading...

Lorem ipsum dolor sit amet consectetur, adipisicing elit. Ipsa vel nobis alias. Quae eveniet velit voluptate quo doloribus maxime et dicta in sequi, corporis quod. Ea, dolor eius? Dolore, vel!

  The passcode will expire in None.
Loading...

No annotations made yet

Add a private note
  • abc Select a piece of text from the left.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.